Amplifier

Dacell is providing ultra-precision load cells and various weighting and measuring products,
which can be used in various fields of industries, based on 20 years of experiences in manufacturing
of weighing and measuring products and with own superior technologies.

833901e023305881db778c2efb239919.jpg
DN-AM1000
The DN-AM1000 Series high precision, as the sensitivity dynamic signal amplifier independence of majority (Multi-channel) it will put in to the 19" rack case and it will be able to use and it is planned. The voltage signal which is output comes to become rate (GAIN) until 1~11000 boats, answer back frequency the maximum 100㎑, the Low Pass Filter is becoming at 10㎐~10㎑.
WP Editor : The DN-AM1000 Series high precision, as the sensitivity dynamic signal amplifier independence of majority (Multi-channel) it will put in to the 19" rack case and it will be able to use and it is planned.
The voltage signal which is output comes to become rate (GAIN) until 1~11000 boats, answer back frequency the maximum 100㎑, the Low Pass Filter is becoming at 10㎐~10㎑.


Feature

  • Fully adjustable calibrated gain from 1 to 11000
  • Accepts all strain gage inputs(foil or piezoresistive), potentiometer, LVDT, etc.
  • Bridge excitation from 1 to 10Vdc(5 steps)
  • Input impedance above 1GΩ.
  • Four-frequency low-pass active filter (10㎐ to 10㎑)
  • Automatic bridge balance (± 4000με)
  • Double shunt calibration (120Ω, 350Ω, 2000με, 200με)
  • Outputs voltage display (7-segment 4-digits LED)
  • Size : 218 (H) × 43 (W) × 258 (D) (㎜)
  • Weight : Approx. 1.2㎏


Connector

  • Signal input : MS3112E 14-19S, MS3116F 14-19P
  • Signal output : BNC connector


DIMENSIONS





SPECIFICATIONS

SPECIFICATIONS TABLE
Specifications Accuracy
EXCITATION 5 steps : 1V, 2V, 5V, 7.5V, 10V
Current : 170mA, max.
Remote sense error : 0.0005%/Ω at lead resistance (350Ω load)
Noise and ripple : 0.05% p-p, max (dc 10㎑)
Stability : ± 0.02%/℃
INPUT StrAIN GAUGE :
quarter, half or full bridge (50~1000Ω)
Built-in 120Ω and 350Ω dummy resister
trANSDUCER :
Piezoresistive strain gauge types,potentiometer, DCDT transducers displacement.
AMPLIFIER 1st Gain : ×1, ×10, ×100, ×400, ×1000 5steps (accuracy ±1%)
2nd Gain : ×1 to ×11 continuously variable
Vernier multiplier : 10-turn counting knob with direct readout (×1 to ×11)
Frequence response : 100㎑ (-3㏈), max
Input resistance : 1GΩ, differential or common mode
Input capacitance : 4pF, differential or common mode
Input voltage range :
± 10V, differential mode
12V-(G/2× Vd), common mode (Vd = actual differential input voltage)
Bias current : ± 30nA, typical, each input
Common-mode rejection (G=100) : 100㏈, min, dc to 60㎐ with 1kΩ source imbalance
Stability (G<1000) : 5ppm/℃, max
Noise (G=100) : 0.01 to 10㎐, 0.3μVp-p R.T.I
FILTER Characteristic : low-pass active 2-pole Butterworth standard
Frequencies (-3㏈) : 10㎐, 100㎐, 1㎑, 10㎑, wide-band
AMPLIFIER OUTPUT
(BNC CONNECTOR)
Outputs : ±10V @100mA max. (out1); ±10V @10mA max. (out2)
Linearity : ±0.01%
VOLTAGE DISPLAY Display character : 7-segment 4-digits LED
Display range : 0.000V ~ ± 10.00V
GAIN 5 steps Amplilfier (x1, x10, x100, x400, x1000)
FREQUENCY RESPONSE 100㎑ (-3㏈), Max
BRIDGE BALANCE Auto ranging : ± 4000με (2mV/V)
Auto balance time : 1 second, typical
Manual balance range : ± 1V
Storage : non-volatile data memory (EEPROM)
LOW PASS FILTER 4 steps 10㎐, 100㎐, 1㎑, 10㎑ (-3㏈)
LINEARITY ±0.01%
STABILITY ±0.01%℃
SHUNT CALIBRATION Bridge resistance 120Ω : 200με and 2000με calibrations
Bridge resistance 350Ω : 200με and 2000με calibrations
INPUT IMPEDANCE more than 1GΩ
POWER AC 110V or 220V (switch selected), 50/60㎐, 7.5watts
3-wirecode ( 2-wire : power / 1-wire : Ground)