Load Cells

Dacell is providing ultra-precision load cells and various weighting and measuring products,
which can be used in various fields of industries, based on 20 years of experiences in manufacturing
of weighing and measuring products and with own superior technologies.

tx25-t.jpg
TX25
Model TX25 load cells measure both tension & compression load force. Applications include performance testers for automotive industry.
WP Editor : Model TX25 load cells measure both tension & compression load force. Applications include performance testers for automotive industry.

Specifications

Specifications Accuracy
Rated capacity(R.C.) 1tf, 2tf, 3tf, 5tf, 10tf
Rated output(R.O.) 1mV/V
Nonlinearity 0.15% of R.O.
Hysteresis 0.15% of R.O.
Repeatability 0.1% of R.O.
Creep 0.05% of R.O.
Zero balance ±1% of R.O.
Excitation recommended 10V
Terminal resistance input, output 350Ω±1%
Insulation resistance bridge 2000㏁
Temperature range, compensated -10~60℃
Temperature range, safe -20~80℃
Temp. effect on rated output ±0.01% of LOAD/10℃
Temperature effect, on zero balance ±0.02% of R.O./10℃
Safe overload 120% R.C
Cable length Φ5, 4core, 3m
 

Dimensions Table

 TX25.png


Model Capacity A B ΦC D E Weight(kg)
TX25-K100 100kgf (980.7N) 75 35 28 M16×1.5 20 0.5
TX25-K200 200kgf (1.961KN) 75 35 28 M16×1.5 20
TX25-K500 500kgf (4.903KN) 75 35 28 M16×1.5 20
TX25-T1 1tf (9.807KN) 75 35 28 M20×1.5 20
TX25-T2 2tf (19.61KN) 75 35 28 M20×1.5 20
TX25-T3 3tf (29.42KN) 75 35 28 M20×1.5 20
TX25-T5 5tf (49.03KN) 75 35 33 M24×2 20 0.7
TX25-T10 10tf (98.07KN) 170 100 62.5 M39×2 35 2.5
TX25-T20 20tf (196.1KN) 190 100 63 M39×2 50 2.8
TX25-T50 50tf (490.3KN) 245 105 85 M64×2 70 7.5
TX25-T100 100tf (980.7KN) 340 140 115 M80×2 100 18
TX25-T200 200tf (1961KN) 390 160 150 M110×2 115 36
TX25-T300 300tf (2942KN) 450 194 169 M125×4 128 46
★Specifications are subiect to change without notice.