빠른 데이터 처리
Mounting type: 35 mm DIN rail 장착
보정은 전면 덮개로 보호되는 세개의 버튼으로 설정.
탈착식 screw terminal blocks.
작은 폭의 사이즈로 판넬에 많은 수의 인디케이터 설치가능.
multiple serial interfaces (RS485, RS232, ASCII and Modbus RTU protocols)
The analog output (0~20 mA, 4~20 mA, 0~10 Vdc, 0~5 Vdc)
The functions of ZERO and CALIBRATION as well as datasheet and real calibration.
Two SET POINTs
빠른 데이터 처리
Mounting type: 35 mm DIN rail 장착
보정은 전면 덮개로 보호되는 세개의 버튼으로 설정.
탈착식 screw terminal blocks.
작은 폭의 사이즈로 판넬에 많은 수의 인디케이터 설치가능.
multiple serial interfaces (RS485, RS232, ASCII and Modbus RTU protocols)
The analog output (0~20 mA, 4~20 mA, 0~10 Vdc, 0~5 Vdc)
The functions of ZERO and CALIBRATION as well as datasheet and real calibration.
Two SET POINTs
AVAILABLE VERSION:
• DAT 11/A: version with the analog output.
• DAT 11/PROFINET: weight transmitter with RS232 serial output, USB and PROFINET.
• DAT 11/ETHERNET IP: weight transmitter with serial output RS232 and ETHERNET IP.
• DAT 11/ETHERCAT: weight transmitter with serial output RS232 and ETHERCAT.
• DAT 11/ETHERNET: weight transmitter with serial output RS232 and ETHERNET.
• DAT 11/PROFIBUS: weight transmitter with serial output RS232 and PROFIBUS.
• DAT 11/CANOPEN: weight transmitter with serial output RS232 and CANOPEN.
Measuring range: -7.6 ~ +7.6 mV/V |
Input sensitivity: 0.02 µV/count |
Full scale non-Linearity: <0.01% |
Gain drift: < 0.002% FS/°C |
Display: 6 digit, 7-segment LED red, height 8mm |
A/D Converter: 24 bit |
Internal Resolution: > di 16.000.000 points |
Frequency signal acquisition: 13 ~ 1.000 Hz |
Visible resolution (in divisions): 999999 |
Divisions value (adjustable): x1, x2, x5, x10, x20, x50 |
Decimal figures range: 0 ~ 4 |
Temperature range: -10 ~ +50°C (max umidity 85% without condensation) |
Storage temperature: -20 ~ +60°C |
Filter: 0.1 ÷ 250 Hz |
Excitation voltage: 4 Vdc (max 4 -350 Ohm- load cells) |
Logic output: 2 optoisolated outputs; max 24 Vdc/100 mA each |
Logic input: 2 optoisolated inputs 24 Vdc PNP (external power supply) |
Serial port: 1 USB-C device + 1 RS232C + 1 RS485/Fieldbus; ASCII or Modbus RTU protocol |
Analog output Non-Linearity: <0.03% |
Temperature drift analog output: 0,002% FS / °C |
Power supply: 24 Vdc ±10% - power consumption 5 W |
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard via USB |
Data storage: 32 Kbytes expandable up to 1024 Kbytes (optional) |
Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety; EN45501 for Metrology |